TCO Calculator

How much will GRC immersion cooling save you? Simply fill in the fields below to match your operation and click ‘Calculate’ to find out.

W
U
Servers

0

per kWh

In creating this online savings calculator, GRC made assumptions using industry application averages. GRC does not make any representation or warranty, express or implied, as to the accuracy of the calculator's results, which are hypothetical and may not reflect the actual savings of your own purchases. GRC is not responsible for the consequences of any decisions or actions taken in reliance upon or as a result of the information provided by this calculator.

Total Cost of Ownership Over 10 Years

GRC Saves You0%
Traditional TCO
GRC TCO
10-Year Savings

Operational Expenses

  • GRC
  • Traditional
Energy
0%Annual Savings $
Total PUE
Total Power kW
kW
Annual Energy Use kWh
kWh
Annual Energy Cost $
$
Maintenance
0%Annual Savings $
Annual Maintenance Costs $
$

Capital Expenditures

0%Savings $
Total CAPEX $
$

Upfront Costs & Power Overheads:

Category Value/UOM Source/Notes
Server Power Savings 18% Benchmark from USAF test results (some applications as high as 30%)
Chiller Overhead 25% of IT Load Customer Validated Data
Chiller Cost $0.34/Watt Based on $1,500/ton and 20% FOS (Factor of Safety)
GRC CDU Cooling Overhead 2% of IT & Cooling Power Customer Validated Data
Cooling Tower Overhead 2% of IT & Cooling Power Customer Validated Data
Cooling Tower Cost $0.22/Watt Customer Validated Data
Raised Floor $30/Sq Ft Panels $17-30/Sq Ft, plus Installation Labor
Air Handler Overhead 10% of IT Load Customer Validated Data
Air Handler Cost $0.62/Watt Vendor Quotes & Customer Data
UPS Cost $0.92/Watt Vendor Quotes & Customer Data
Diesel Generator & Switch Gear Cost $0.29/Watt Vendor Quotes & Customer Data
Electrical Infrastructure & Power Distribution Cost $0.42/Watt Vendor Quotes & Customer Data
Maintenance Cost 3% of Upfront Cost Forrester: http://www.onepartner.com/data-center-costs
Annual Maintenance Cost Increase 1% Accounting for Inflation
Annual Energy Cost Increase 1% Accounting for Inflation
Power Distribution Losses 6% of Total Power Data Center Dynamics: DCPRO: Cooling & Thermal Management Paper
Air Cooling Max Rack Density 15 kW/Rack Customer feedback
Fully Loaded Floor Space/Rack for Air Cooling 79 Sq Ft/Rack Green Grid Estimate
Cost of GRC System $0.96/Watt
Plumbing & Ducting for Air-Cooled $0.60/Watt Customer Validated Data
Plumbing Costs GRC $0.30/Watt Customer Validated Data
Sensors & Controls $0.15/Watt Customer Validated Data
Traditional Data Center Engineering and Design Services 20% of Total Cost Forrester: http://www.onepartner.com/data-center-costs
GRC Data Center Engineering & Design Services 10% of Total Cost Customer feedback
Cost of Traditional Racks $1,500.00/Rack Vendor Quotes & Customer Data

Space (Traditional):

Category Value/UOM Source
Rack Size 42U
Top of Rack (TOR Switches) 2U
Server Capacity Rack 40U
Width (Length for GRC) 26.62 Inches Liebert 42U: http://www.42u.com/42U-cabinets.htm
Depth (Width for GRC) 43.3 Inches Liebert 42U: http://www.42u.com/42U-cabinets.htm
Cold Aisle Width 48 Inches ANSI/TIA/ EIA-942-A (data center) standard: https://www.conteg.com/hot-cold-aisle
Hot Aisle Width 36 Inches ANSI/TIA/ EIA-942-A (data center) standard: https://www.conteg.com/hot-cold-aisle
Supported Density 15 kW/Rack Customer Feedback
Racks/Row 12 Calculated to get similar row width
Row Width 34.62 Feet Including 4 ft aisle at each end

Space (GRC):

Category Value/UOM Source
Rack Size 42U
Top of Rack Switches 0U Switch pockets in the back of the GRC rack allow for more server capacity in rack
Server Capacity/Rack 42U
Width (Length for GRC) 85 Inches
Depth (Width for GRC) 25 Inches
Cold Aisle Width 36 Inches
Hot Aisle Width 2 Inches
Supported Density 120 kW/Rack Conservative estimate, 130kW+ achieved
Racks/Row 4
Row Width 35.94 Feet

Space Cost:

Category Value/UOM Source
Traditional Site Preparation Cost $150.00/Sq Ft Forrester: http://www.onepartner.com/data-center-costs
GRC Site Preparation Cost $150.00/Sq Ft

Bring the Most Efficient Cooling Technology to Your Data Center

To have our representative get in touch with you complete the form below or call: +1.512.692.8003